The command station polls are connected to feedback encoder LR101 in series, this process lasts approximately 30 msec. Only the LR101 encoders with a change in status are transmitting information back to the command station, a transmission from an LR101 needs app. 2 msec, which adds to the polling time, the total length of the cycle is therefore dependent on the number of status changes.